RE: VC 2.1 to 2.3

$
0
0

We created support incident 2878817 for this and I was able to reproduce the problem in a small cutdown managed app so I created an RPI for this and sent to development.

There appears to be a problem with the compiler in 2.3 or higher where it is generating incorrect code when there is a constructor containing and open statement and a GO TO. This results in an exception being thrown when the constructor is called that the CLR detected an invalid program.

The cutdown code looks like:

      class-id Amends.

      INPUT-OUTPUT SECTION.

      FILE-CONTROL.

         select test-file assign to "testfile.dat".

      DATA DIVISION.

      FILE SECTION.

      fd test-file.

      01 test-record  pic x(20).

      WORKING-STORAGE SECTION.

      01  XREPLY                       PIC X.

      method-id NEW.

      procedure division.

      IN010.

          OPEN INPUT test-file.

          IF XREPLY = "X" GO TO IN010.

          goback.

      end method.

      end class.

If I comment out either the OPEN statement or the IF statement then the problem does not occur.

If I rewrite the code to use perform instead of GO TO then it also works.

IN010.

          perform until exit

               OPEN INPUT test-file

               IF not XREPLY = "X"

                   exit perform

               end-if

          end-perform

          goback.

I will keep you updated through the support incident.